APC Back-UPS Connect 90, 120V, Network backup, USB charging ports
APC Back-UPS Connect, 75 Watts /125 VA, Input 120V /Output 120V
Includes: User Manual
Sorry, this product is no longer available, Please contact us for a replacement.
*Please note: Product descriptions, specifications and part numbers have been sourced from www.apc.com and may refer to the US products which differ from products which will be supplied in Australia. Data sheets can be provided upon request for the Australian equivalent to these products.
Extended Runtime UPS for Network Gateway Devices
Back-UPS Connect is an innovative UPS product family that is designed to power networking equipment for prolonged periods of time during blackouts. Run a router, modem and other low-power devices for 3 to 5 hours during a power outage. Access to the internet is a critical component of our personal and professional lives. Unfortunately, power outages break our lines of communication for business operations, news and weather updates, and restrict us from contacting friends and family. At APC by Schneider Electric, we understand the network is critical to your everyday life. Back-UPS Connect will keep your network running, even when the power goes out.
You depend on your network every day. Stay connected to the Internet during power outages by backing up home networking equipment and charging your smart devices with Back-UPS Connect.
- Get news/weather updates
- Make phone/video calls
- Check email
- Update social media
- Maintain home automation and security systems
- Stream movies
- Continue gaming
Storms and power outages can easily sever your network connection, just when you need it the most. Losing Internet access breaks our line of communication for business operations, news and weather updates, and restricts us from contacting friends and family. The BGE90M will keep your network up and running for hours and charge your mobile devices as needed.
- 4.5 hours of network power for extended outages. An efficient design maximizes runtime for low-power devices, even outperforming larger UPSes on equivalent low-power loads.
- Two convenient USB ports to recharge smartphones and tablets.
- Computer-grade surge protection protects your devices from surges and spikes.
- Fast recharge of the internal battery ensures you're ready for the next outage.
- Best-in-Class 3 Year Warranty ensures peace of mind. Additionally, we provide a $75 000 lifetime equipment protection policy and free technical support.
Features & Benefits:
Features | |
Battery and surge protected outlets | Back up and protect your hardware and data during power outages, surges and spikes. |
USB charging ports | Simultaneously charge mobile devices, including smartphones and tablets. |
Resettable circuit breaker | Easy recovery from overloads; no need to replace a fuse. |
Protection | |
Battery backup and surge protection | Outlets provide abundant runtime for network gateway equipment and other critical low-power devices, allowing for hours of internet access during a power outage. |
Serviceability | |
Simple battery replacement | Increases UPS availability by allowing quick, easy battery replacement. |
Resettable circuit breaker | Easy recovery from overloads; no need to replace a fuse. |
Manageability | |
LED status display | Quickly understand unit and power status with visual indicators. |
Technical Specifications:
Output | |
Output Power Capacity | 75 Watts / 125 VA |
Max Configurable Power | 75 Watts / 125 VA |
Nominal Output Voltage | 120V |
Output Frequency (sync to mains) | 50/60 Hz +/- 1 Hz |
Waveform Type | Square wave |
Output Connections | (3) NEMA 1-15R (Battery Backup) |
Input | |
Nominal Input Voltage | 120V |
Input Frequency | 50/60 Hz |
Input Connections | NEMA 5-15P |
Cord Length | 5 feet (1.52 meters) |
Input voltage range for main operations | 90 - 140V |
Input Breaker Capacity | 4 A |
Batteries & Runtime | |
Battery Type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
Typical recharge time | 6 hour(s) |
Replacement Battery (Service center technician only) | APCRBC106 |
Runtime Graph |
Hover over the line on the graph above to view the efficiency at any desired load Curve fit of data measured in accordance with the ENERGY STAR Program Requirements Product Specification for Uninterruptible Power Supplies (UPSs) - Eligibility Criteria Version 1.0. All measurements taken in normal mode(s), at typical environmental conditions, with 120V/60Hz electrical input and balanced resistive load (PF = 1.0) output. |
Communications & Management | |
Control Panel | LED status display with On Line : On Battery : Replace Battery and Overload indicators |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering | |
Surge Energy Rating | 120 Joules |
Physical | |
Maximum Height | 5.20 inches (132 mm) |
Maximum Width | 4.13 inches (105 mm) |
Maximum Depth | 8.86 inches (225 mm) |
Net Weight | 6.61 lbs. (3.00 kg) |
Shipping Weight | 7.28 lbs. (3.30 kg) |
Shipping Height | 8.03 inches (204 mm) |
Shipping Width | 6.46 inches (164 mm) |
Shipping Depth | 11.77 inches (299 mm) |
Master Carton Units | 2.00 |
Master Carton Weight | 15.43 lbs. (7.00 kg) |
Color | White |
SCC Codes | 1073130431411 7 |
Units per Pallet | 72.00 |
# of Layers per Pallet | 4 |
Environmental | |
Operating Environment | 32 - 104°F (0 - 40°C) |
Operating Relative Humidity | 0 - 95% |
Operating Elevation | 0-3000 feet (0-900 meters) |
Storage Temperature | 5 - 113°F (-15 - 45°C) |
Storage Relative Humidity | 0 - 95% |
Storage Elevation | 0-15000 feet (0-4500 meters) |
Audible noise at 1 meter from surface of unit | 45.00 dBA |
Conformance | |
Regulatory Approvals | California (CEC) Battery Charger, FCC Part 15 Class B, NOM, TUV-NURTL |
Standard Warranty | 3 years repair or replace |
Equipment protection policy | Lifetime : $75000 |
Sustainable Offer Status | |
RoHS | Compliant |
REACH | REACH: Contains No SVHCs |
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.
Documentation:
Download the APC BGE90M Datasheet (.PDF)