APC Smart-UPS 3000VA LCD 120V
APC Smart-UPS, 2700 Watts / 3000 VA,Input 120V / Output 120V, Interface Port USB
Includes: CD with software, Documentation CD, Smart UPS signalling RS-232 cable, USB cable
Sorry, this product is no longer available, please contact us for a replacement.
*Please note: Product descriptions, specifications and part numbers have been sourced from www.apc.com and may refer to the US products which differ from products which will be supplied in Australia. Data sheets can be provided upon request for the Australian equivalent to these products.
Over 20 million units sold - the UPS you can trust
APC award-winning Smart-UPS® is the most popular UPS in the world for servers, storage and networks. Trusted to protect critical data and equipment from power problems by supplying clean and reliable network-grade power. In addition to legendary reliability and manageability, Smart-UPS have extremely high efficiency at low, medium and high load levels making them ideal for today's multi-core or virtualized servers that have varying load consumption. Available in a variety of form factors (tower, rack mount, rack/tower convertible) there is a model for every application and budget. Rack mounted Smart-UPS are ideal for powering Blade or density optimized servers in a distributed power protection environment as the primary or redundant protection. Smart-UPS® models have long been considered the benchmark for all network and server UPS's. Smart-UPS feature a 16-segment LED display, extended range automatic voltage regulation (AVR), and pure sine wave output on battery. Additional manageability options are available through the Smart-Slot interface, which is an internal slot for the installation of optional accessory cards. The extended run Smart-UPS XL has the capability to add external battery packs to scale runtime from minutes to hours typically needed for converged voice and data networks. The entry level Smart-UPS SC is an economical choice for small and medium businesses looking to protect small switches, networking devices and point-of-sale (POS) equipment.
SMT3000 Feature Overview:
- Intuitive LCD interface - Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
- Predictive replace battery date - Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
- Green mode - Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Energy meter - Provides actual kilowatt hours of usage for energy conscious users.
- Audible alarms - Provide notification of changing flywheel conditions
- InfraStruXure Central compatible - Enables centralized management via APC InfraStruXure® Central.
- Pure sine wave output on battery - Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Single switched outlet group - Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
- Battery failure notification - Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- SmartSlot - Customize UPS capabilities with management cards.
- Cold-start capable - Provides temporary battery power when the utility power is out.
- Serial Connectivity - Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
- Resettable circuit breakers - Enables a quick recovery from overload events.
- Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Disconnected battery notification - Warns when a battery is not available to provide backup power.
- Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Automatic restart of loads after UPS shutdown - Automatically starts up the connected equipment upon the return of utility power.
- Adjustable voltage-transfer points - Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Adjustable voltage sensitivity - Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Audible alarms - Provides notification of changing utility power and UPS conditions.
- User-replaceable batteries - Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- USB connectivity - Provides management of the UPS via a USB port (not available on all models).
- Serial Connectivity - Provides management of the UPS via a serial port.
- Temperature-compensated battery charging - Prolongs battery life by regulating the charge voltage according to battery temperature.
- Boost and Trim Automatic Voltage Regulation (AVR) - Gives higher application availability by correcting low and high voltage conditions without using the battery.
- Intelligent battery management - Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Safety-agency approved - Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Power conditioning - Protects connected loads from surges, spikes, lightning, and other power disturbances.
- Network manageable - Provides remote management of the UPS over the network.
- Adjustable voltage sensitivity - Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.
- Predicitive failure notification - Provides early-warning fault analysis ensuring proactive component replacement.
Features & Benefits:
Availability | |
Boost and Trim Automatic Voltage Regulation (AVR) | Gives higher application availability by correcting low and high voltage conditions without using the battery. |
Intelligent battery management | Maximizes battery performance, life, and reliability through intelligent, precision charging. |
Power conditioning | Protects connected loads from surges, spikes, lightning, and other power disturbances. |
Temperature-compensated battery charging | Prolongs battery life by regulating the charge voltage according to battery temperature. |
Automatic restart of loads after UPS shutdown | Automatically starts up the connected equipment upon the return of utility power. |
Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
Cold-start capable | Provides temporary battery power when the utility power is out. |
Disconnected battery notification | Warns when a battery is not available to provide backup power. |
Manageability | |
Network manageable | Provides remote management of the UPS over the network. |
Audible alarms | Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. |
LED status indicators | Quickly understand unit and power status with visual indicators. |
Serial Connectivity | Provides management of the UPS via a serial port. |
USB connectivity | Provides management of the UPS via a USB port (not available on all models). |
Disconnected battery notification | Warns when a battery is not available to provide backup power. |
Serviceability | |
User-replaceable batteries | Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
Predictive failure notification | Provides early-warning fault analysis ensuring proactive component replacement. |
Resettable circuit breakers | Enables quick recovery from UPS overload events. |
Adaptability | |
Adjustable voltage-transfer points | Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. |
Adjustable voltage sensitivity | Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. |
Field-replaceable power distribution panel | Ensures compatibility with equipment that has different plug types. |
Safety | |
Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |
Runtime Chart:
Click here to view the Smart-UPS Runtime Chart. (pop-up window)
Technical Specifications:
Output | |
Output Power Capacity | 2700 Watts / 3000 VA |
Max Configurable Power | 2700 Watts / 3000 VA |
Nominal Output Voltage | 120V |
Efficiency at Full Load | 98% |
Output Frequency (sync to mains) | 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal |
Output Voltage Distortion | Less than 5% at full load |
Waveform Type | Sine wave |
Output Connections | (8) NEMA 5-15R (2) NEMA 5-20R |
Input | |
Nominal Input Voltage | 120V |
Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
Input Connections | NEMA L5-30P |
Cord Length | 6 feet (1.83 meters) |
Input voltage range for main operations | 82 - 144V |
Input voltage adjustable range for mains operation | 75 - 154V |
Batteries & Runtime | |
Battery Type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof |
Typical recharge time | 3 hour(s) |
Replacement battery cartridge | RBC55 |
RBC™ Quantity | 1 |
Runtime Graph |
Hover over the line on the graph above to view the runtime at any desired load Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. |
Energy Use/Efficiency | |
Hover over the line on the graph above to view the efficiency at any desired load Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. |
|
Communications & Management | |
Interface Port(s) | USB |
Available SmartSlot™ Interface Quantity | 1 |
Control panel | Multi-function LCD status and control console |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : configurable delays |
Emergency Power Off (EPO) | Yes |
Surge Protection and Filtering | |
Surge Energy Rating | 530 Joules |
Filtering | Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Physical | |
Maximum Height | 17.00 inches (432 mm) |
Maximum Width | 7.70 inches (196 mm) |
Maximum Depth | 21.50 inches (546 mm) |
Net Weight | 116.00 lbs. (52.73 kg) |
Shipping Weight | 134.00 lbs. (60.91 kg) |
Shipping Height | 22.00 inches (559 mm) |
Shipping Width | 15.00 inches (381 mm) |
Shipping Depth | 30.00 inches (762 mm) |
Color | Black |
Units per Pallet | 3.00 |
Environmental | |
Operating Environment | 32 - 104°F (0 - 40°C) |
Operating Relative Humidity | 0 - 95% |
Operating Elevation | 0-10000 feet (0-3000 meters) |
Storage Temperature | 5 - 113°F (-15 - 45°C) |
Storage Relative Humidity | 0 - 95% |
Storage Elevation | 0-50000 feet (0-15000 meters) |
Audible noise at 1 meter from surface of unit | 45.00 dBA |
Online Thermal Dissipation | 275.00 BTU/hr |
Conformance | |
Regulatory Approvals | CSA, FCC Part 15 Class A, UL 1778 |
Standard Warranty | 3 years repair or replace (excluding battery) and 2 year for battery, optional on-site warranties available, optional extended warranties available |
Equipment protection policy | Lifetime: $150,000 |
Environmental Compliance | RoHS 7b Exemption |