Call a Specialist Today! (02) 9388 1741
Free Delivery! Free Delivery!

APC Smart-UPS SRT 10000VA RM with 208/240V to 120V 10kVA Step-Down Transformer
APC Smart-UPS On-Line, 10000 Watts /10000 VA, Input 208V / Output 120V, 208V, Interface Port RJ-45 Serial, Smart-Slot, USB, Rack Height 10 U

APC Smart-UPS SRT 10000VA RM with 208/240V to 120V 10kVA Step-Down Transformer

This product is not available for purchase in Australia. Please Contact Us for assistance with an appropriate solution.


Includes: CD with software, Documentation CD, Installation guide, Rack Mounting brackets, Rack mounting hardware, Rack Mounting support rails, Temperature Probe, USB cable, User Manual, Warranty card, Web/SNMP Management Card

*Please note: Product descriptions, specifications and part numbers have been sourced from www.apc.com and may refer to the US products which differ from products which will be supplied in Australia. Data sheets can be provided upon request for the Australian equivalent to these products.

A versatile UPS developed for the harshest power conditions in the world.

Smart-UPS On-Line provides high density, true double-conversion on-line power protection for servers, voice / data networks, medical labs, and light industrial applications. Capable of supporting loads from 1 to 20kVA in a rack/tower convertible form, the Smart-UPS On-Line is available from 2U to 12U. Recent family extensions at 15 and 20kVA enable support of power hungry blade servers or heavily loaded equipment racks. When business-critical systems require runtime in hours, not minutes, Smart-UPS On-Line can be configured with matching battery packs to comply with aggressive runtime demands. The included PowerChute management software provides unattended graceful shutdown of network operating systems. All models 5kVA and above include an integrated Network Management Card for remote management (optional on models below 5 kVA). The entire Smart-UPS On-Line family provides value to customers with demanding power environments, including very wide input voltage window, extremely tight output voltage regulation, frequency regulation, internal bypass, and input power factor correction.

SRT10KRMXLT-10KTF Rear
SRT10KRMXLT-10KTF Front Open and Battery Pullout

Features & Benefits:

Features
10/100 BaseT Connection Connect the device to a network using a 10 or 100 BaseT connection
Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
LCD graphics display Text and mimic diagrams that display modes of operation, system parameters and alarms.
Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Availability
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Scalable runtime Allows additional run time to be quickly added as needed.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Manageability
Network manageable Provides remote management of the UPS over the network.
InfraStruXure Manager compatible Enables centralized management via the APC InfraStruXure® Manager.
SmartSlot Customize UPS capabilities with management cards.
LED status indicators Quickly understand unit and power status with visual indicators.
Serial Connectivity Provides management of the UPS via a serial port.
Serviceability
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification Warns when a battery is not available to provide backup power.
Audible alarms Provides notification of changing utility power and UPS conditions.
Adaptability
Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash-upgradeable firmware Install maintenance releases of firmware remotely using FTP.
Protection
Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to the loads in the event of an extended power outage.
Cold-start capable Provides temporary battery power when the utility power is out.
Resettable circuit breakers Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.
Marketing Features
Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry's most rigorous standards.
Avoids costly power problems by keeping your IT equipment and data protected and available. Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Low operating and maintenance costs with proven reliability and intelligent battery management. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Save time with easy and convenient remote accessibility. Network manageable via serial, USB or optional Ethernet. Includes Powerchute Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.

Technical Specifications:

Output
Output Power Capacity 10000 Watts / 10000 VA
Max Configurable Power 10000 Watts / 10000 VA
Nominal Output Voltage 120V , 208V
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50/60Hz +/- 3 Hz
Other Output Voltages 240
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections (2) NEMA L14-30R (Battery Backup)
(2) NEMA L5-20R (Battery Backup)
(4) NEMA L6-20R (Battery Backup)
(2) NEMA L6-30R (Battery Backup)
(1) Hard Wire 3-wire (2PH + G) (Battery Backup)
Input
Bypass Internal Bypass (Automatic and Manual)
Nominal Input Voltage 208V
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections Hard Wire 3-wire (2PH + G)
Input voltage range for main operations 160 - 275 V
Input voltage adjustable range for mains operation 100 - 275 (half load) V
Other Input Voltages 240
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
Typical recharge time 1.5 hour(s)
Replacement battery cartridge APCRBC140
RBC Quantity 2
Extendable Run Time 1
Battery Volt-Amp-Hour Capacity 1799
Extended Run Options APC-Smart-UPS-SRT-10kVA-RM-with-208-240V-to-120V-10kVA-Step-Down-Transformer
Runtime View Runtime Graph
Efficiency View Efficiency Graph
Communications & Management
Interface Port(s) RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB
Control panel Multi-function LCD status and control console
Audible Alarm Audible and visible alarms prioritized by severity
Emergency Power Off (EPO) Yes
Available SmartSlot Interface Quantity 1
Surge Protection and Filtering
Surge energy rating 480 Joules
Filtering --
Physical
Maximum Height 17.25 inches (438 , 43.8 cm)
Maximum Width 17.0 inches (432 , 43.2 cm)
Maximum Depth 29.5 inches (749 , 74.9 cm)
Net Weight 466.0 lbs. (211.37 kg)
Shipping Weight 561.0 lbs. (254.47 kg)
Shipping Height 34.15 inches (867 , 86.7 cm)
Shipping Width 23.64 inches (600 , 60.0 cm)
Shipping Depth 39.38 inches (1000 , 100.0 cm)
Color Black
Units per Pallet 1.00
Rack Height 10U
Environmental
Operating Environment 32 - 104°F (0 - 40°C)
Operating Relative Humidity 0 - 95%
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature 5 - 113°F (-15 - 45°C)
Storage Relative Humidity 0 - 95%
Storage Elevation 0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit 55.00 dBA
Online Thermal Dissipation 2490.0 BTU/hr
Protection Class IP 20
Conformance
Regulatory Approvals CSA C22.2 No.107.3-05, ENERGY STAR (USA), FCC Part 15 Class A, UL 1778
Standard Warranty 3 years repair or replace (excluding battery) and 2 years for battery