APC Symmetra RM 6kVA Scalable to 6kVA N+1 208/240V
APC Symmetra, 4200 Watts / 6000 VA,Input 208V / Output 208V, Interface Port DB-9 RS-232, RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management, Extended runtime model, Rack Height 8U

APC Symmetra RM 6kVA Scalable to 6kVA N+1 208/240V

This product is not available for purchase in Australia. Please Contact Us for assistance with an appropriate solution.


Includes: CD with software, Rack Mounting brackets, Rack Mounting support rails, User Manual

-->
*Please note: Product descriptions, specifications and part numbers have been sourced from www.apc.com and may refer to the US products which differ from products which will be supplied in Australia. Data sheets can be provided upon request for the Australian equivalent to these products.

The first UPS with redundancy and scalability within a single chassis.

Engineered to deliver the highest level of business continuity possible, Symmetra uses a modular, redundant architecture that can scale power and runtime as demand increases or when higher levels of availability are required. Symmetra’s integrated manageability, and hot-swappable, user replaceable power, battery, and intelligence modules enable easy, fast maintenance and serviceability. Its 2-6kVA N+1 redundant rack-optimized form factor makes Symmetra ideal for protecting critical server racks and network rooms. Typical applications include Web and other key application servers, IP based and traditional PBX voice solutions, and enterprise type network switches.

Features & Benefits:

Availability
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Configurable for N+1 internal redundancy Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
Hot-swappable power modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Battery modules connected in parallel Delivers higher availability through redundant batteries.
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Adaptability
Scalable power capacity Reduces UPS over-sizing costs today by allowing quick upgrades later.
Scalable runtime Allows additional run time to be quickly added as needed.
Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Field-replaceable power distribution panel Ensures compatibility with equipment that has different plug types.
Programmable frequency Ensures compatibility with different input frequencies.
Manageability
Manageable external batteries Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
Network manageable Provides remote management of the UPS over the network.
InfraStruXure Manager compatible Enables centralized management via the APC InfraStruXure® Manager.
LCD display Alpha-Numeric Display which displays system parameters and alarms.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
SmartSlot Customize UPS capabilities with management cards.
Serviceability
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
User-replaceable intelligence modules Enables simple upgrades and replacements of the Intelligence Modules.
User-replaceable power modules Enables simple upgrades and replacements of the Power Modules.
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Disconnected battery notification Warns when a battery is not available to provide backup power.
Protection
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to the loads in the event of an extended power outage ;
Cold-start capable Provides temporary battery power when the utility power is out.
Resettable circuit breakers Enables a quick recovery from overload events.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.

Runtime Chart:

Click here for APC Symmetra Runtime chart. (pop-up window)

Technical Specifications:

Output
Output Power Capacity 4200 Watts / 6000 VA
Max Configurable Power 4200 Watts / 6000 VA
Nominal Output Voltage 208V
Output Voltage Note Configurable for 208 or 240 output voltage
Efficiency at Full Load 89.00%
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominal
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections NEMA L6-20R(2) NEMA L6-20R


NEMA L6-30R(1) NEMA L6-30R
Input
Bypass Internal Bypass (Automatic and Manual)
Nominal Input Voltage 208V
Input Frequency 50/60 Hz +/- 5 Hz (auto sensing)
Input Connections Hard Wire 3-wire (2PH + G)
NEMA L6-30P (30A Twist-Lock)
Cord Length 6 feet (1.83 meters)
Input voltage range for main operations 155 - 276V
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
Included Battery Modules 3
Available Battery Slots --
Typical recharge time 4 hour (s)
Replacement battery cartridge SYBT2
Note: UPS accepts 1-2 battery packs
Typical Backup Time at Half Load 30.3 minutes (2100 Watts)
Typical Backup Time at Full Load 12.7 minutes (4200 Watts)
Runtime Chart Symmetra
Extended Run Options APC Symmetra RM 6kVA Scalable to 6kVA N+1 208/240V
Communications & Management
Interface Port(s) DB-9 RS-232, RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management
Available SmartSlot™ Interface Quantity 1
Pre-Installed SmartSlot™ Cards AP9619
Control panel Multi-function LCD status and control console
Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays
Emergency Power Off (EPO) Yes
Physical
Maximum Height 14.00 inches (356 mm)
Maximum Width 19.00 inches (483 mm)
Maximum Depth 28.75 inches (730 mm)
Net Weight 294.00 lbs. (133.64 kg)
Shipping Weight 327.00 lbs. (148.64 kg)
Shipping Height 20.00 inches (508 mm)
Shipping Width 23.00 inches (584 mm)
Shipping Depth 31.00 inches (787 mm)
Color Black
Units per Pallet --
Rack Height 8U
Environmental
Operating Environment 32 - 104°F (0 - 40°C)
Operating Relative Humidity 0 - 95%
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature 5 - 113 °F (-15 - 45 °C)
Storage Relative Humidity 0 - 95%
Storage Elevation 0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit 60.00 dBA
Online Thermal Dissipation 1771.00 BTU/hr
Conformance
Regulatory Approvals CSA,FCC Part 15 Class A,UL 1778
Standard Warranty 2 years repair or replace, optional on-site warranties available,optional extended warranties available
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.